Skip to main content Skip to main navigation menu Skip to site footer
Short communication
Austral J. Vet. Sci.
Vol 58, e5817 (2026)

Association between axillary and rectal temperatures in clinically healthy rabbits from the UNAM Exotic Pet and Wildlife Teaching Hospital

1 Zoological Medicine and Surgery Internship, Faculty of Veterinary Medicine and Zootechnics, National Autonomous University of Mexico, 3000 University Avenue, University City, 04510, Mexico City, Mexico.
2 Department of Genetics and Biostatistics, Faculty of Veterinary Medicine and Zootechnics, National Autonomous University of Mexico, 3000 University Avenue, University City, 04510, Mexico City, Mexico.
3 Ethology, Wildlife and Laboratory Animal Department, Faculty of Veterinary Medicine and Zootechnics, National Autonomous University of Mexico, 3000 University Avenue, University City, 04510, Mexico City, Mexico.
Keywords: rabbit thermometry body temperature rectal temperature axillary temperature

Submitted: 2026-06-05

Accepted: 2026-09-16

Published: 2026-10-07

*Corresponding author:
itzcoatl.maldonado@fmvz.unam.mx

How to Cite

Rivero-Rodríguez, A., Sánchez-González, M. G., & Maldonado-Reséndiz, I. (2026). Association between axillary and rectal temperatures in clinically healthy rabbits from the UNAM Exotic Pet and Wildlife Teaching Hospital . Austral Journal of Veterinary Sciences, 58, e5817. https://doi.org/10.4206/ajvs.58.17

Abstract

Accurate measurement of body temperature is essential for the clinical evaluation of rabbits. Although rectal temperature (RT) measurement is the standard method, obtaining RT measurements can be stressful for patients. Axillary temperature (AT) measurement is proposed as a less invasive alternative; however, the reliability of AT measurements in rabbits has not been sufficiently evaluated. This study aimed to determine the association between AT and RT measurements in clinically healthy rabbits and to evaluate whether AT measurement can be a reliable alternative to RT measurement. Thirty-nine clinically healthy rabbits treated at the UNAM Exotic Pet and Wildlife Teaching Hospital were evaluated between December 2024 and February 2025. Three measurements of AT and RT were recorded for each individual using a flexible digital thermometer. Averages were calculated, and statistical tests were performed to evaluate differences and correlations between AT and RT. No significant differences were observed in either axillary temperature (P = 0.061) or rectal temperature (P = 0.072) between rabbits. AT was significantly lower than RT, with a mean difference of 2.32 °C (95 % CI: 2.05 – 2.58, P < 0.001). The average AT was 36.37 °C and the average RT was 38.68 °C. RT demonstrated greater repeatability, and the agreement between the two methods was insufficient to consider them interchangeable in clinical practice. Furthermore, the difference between AT and RT increased slightly with increasing body temperature (P = 0.028) and was influenced by body weight (P = 0.003) and body condition score (P = 0.033). AT was not correlated with RT in clinically healthy rabbits, indicating that AT measurement is not a reliable alternative for assessing body temperature in this species. The use of RT measurement as a standard method in clinical practice is recommended.

Downloads

Download data is not yet available.

References

  1. Aguilar, L. A. B., Chávez, J. O., & Watty, A. D. (2019). Comparison of body temperature acquired via auricular and rectal methods in ferrets. Journal of Exotic Pet Medicine, 28, 148–153. https://doi.org/10.1053/j.jepm.2018.01.004
  2. Beyer, O., Lueck, A., & Brundage, C. (2023). Comparison of Axillary versus Rectal Temperature Timing in Canine and Feline Patients. Veterinary Sciences, 10(7), 475. https://doi.org/10.3390/vetsci10070475
  3. Chen, P. H., & White, C. E. (2006). Comparison of rectal, microchip transponder, and infrared thermometry techniques for obtaining body temperature in the laboratory rabbit (Oryctolagus cuniculus). Journal of the American Association for Laboratory Animal Science, 45(1), 57–63. http://www.ncbi.nlm.nih.gov/pubmed/16539337
  4. Cichocki, B., Dugat, D., & Payton, M. (2017). Agreement of Axillary and Auricular Temperature with Rectal Temperature in Systemically Healthy Dogs Undergoing Surgery. Journal of the American Animal Hospital Association, 53(6), 291–296. https://doi.org/10.5326/JAAHA-MS-6500
  5. Cugmas, B., Šušterič, P., Gorenjec, N. R., & Plavec, T. (2020). Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer. Veterinary and Animal Science, 9, 100120. https://doi.org/10.1016/j.vas.2020.100120
  6. Giannetto, C., Acri, G., Pennisi, M., Piccione, G., Arfuso, F., Falcone, A., Giudice, E., & Di Pietro, S. (2022). Short Communication: Use of Infrared Thermometers for Cutaneous Temperature Recording: Agreement with the Rectal Temperature in Felis catus. Animals, 12(10), 1275. https://doi.org/10.3390/ani12101275
  7. Girod, M., Vandenheede, M., Farnir, F., & Gommeren, K. (2016). Axillary temperature measurement: a less stressful alternative for hospitalised cats? Veterinary Record, 178(8), 192–192. https://doi.org/10.1136/vr.103580
  8. Goic, J. B., Reineke, E. L., & Drobatz, K. J. (2014). Comparison of rectal and axillary temperatures in dogs and cats. Journal of the American Veterinary Medical Association, 244(10), 1170–1175. https://doi.org/10.2460/javma.244.10.1170
  9. Goig, M., Godino, J., Tejedor, M. T., & Burgio, F. (2024). Correlation of temperature-sensing microchip and rectal temperature measurements in cats. Frontiers in Veterinary Science, 10, 1319722. https://doi.org/10.3389/fvets.2023.1319722
  10. Gomart, S. B., Allerton, F. J. W., & Gommeren, K. (2014). Accuracy of different temperature reading techniques and associated stress response in hospitalized dogs. Journal of Veterinary Emergency and Critical Care, 24(3), 279–285. https://doi.org/10.1111/vec.12155
  11. Greer, R. J., Cohn, L. A., Dodam, J. R., Wagner-Mann, C. C., & Mann, F. A. (2007). Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs. Journal of the American Veterinary Medical Association, 230(12), 1841–1848. https://doi.org/10.2460/javma.230.12.1841
  12. Hall, E. J., & Carter, A. J. (2017). Comparison of rectal and tympanic membrane temperature in healthy exercising dogs. Comparative Exercise Physiology, 13(1), 37–44. https://doi.org/10.3920/CEP160034
  13. Hall, E. J., Fleming, A., & Carter, A. J. (2019). Investigating the use of non-contact infrared thermometers in cats and dogs. The Veterinary Nurse, 10(2), 109–115. https://doi.org/10.12968/vetn.2019.10.2.109
  14. Hartinger, J., Külbs, D., Volkers, P., & Cussler, K. (2003). Suitability of temperature-sensitive transponders to measure body temperature during animal experiments required for regulatory tests. ALTEX, 20(2), 65–70. http://www.ncbi.nlm.nih.gov/pubmed/12764542
  15. Hepps Keeney, C. M., Hung, C. S., & Harrison, T. M. (2021). Comparison of body temperature using digital, infrared, and tympanic thermometry in healthy ferrets (Mustela putorius furo). Journal of Exotic Pet Medicine, 36, 16–21. https://doi.org/10.1053/j.jepm.2020.10.005
  16. Jaén-Téllez, J. A., Bartolomé, E., Sánchez-Guerrero, M. J., Valera, M., & González-Redondo, P. (2021). Relationship between rectal temperature measured with a conventional thermometer and the temperature of several body regions measured by infrared thermography in fattening rabbits. Influence of different environmental factors. World Rabbit Science, 29(4), 263–273. https://doi.org/10.4995/wrs.2021.15556
  17. Khayri, A., Hussein, H. A., Sayed, R., & Waly, N. (2023). Assessment of Thermometry Practices in Dogs Undergoing General Health Examinations. Assiut Veterinary Medical Journal, 69(178), 24–33. https://doi.org/10.21608/avmj.2023.203699.1140
  18. Konietschke, U., Kruse, B. D., Müller, R., Stockhaus, C., Hartmann, K., & Wehner, A. (2014). Comparison of auricular and rectal temperature measurement in normothermic, hypothermic, and hyperthermic dogs. Tierarztliche Praxis. Ausgabe K, Kleintiere/Heimtiere, 42(1), 13–19. http://www.ncbi.nlm.nih.gov/pubmed/24518943
  19. Koo, T. K., & Li, M. Y. (2016). A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. Journal of Chiropractic Medicine, 15(2), 155–163. https://doi.org/10.1016/j.jcm.2016.02.012
  20. Lamb, V., & McBrearty, A. R. (2013). Comparison of rectal, tympanic membrane and axillary temperature measurement methods in dogs. Veterinary Record, 173(21), 524–524. https://doi.org/10.1136/vr.101806
  21. Levy, I., Allender, M. C., & Keller, K. A. (2020). Comparison of axillary and inguinal body temperature to rectal temperature in healthy guinea pigs (Cavia porcellus). Journal of Exotic Pet Medicine, 34, 1–5. https://doi.org/10.1053/j.jepm.2020.03.016
  22. Martin Bland, J., & Altman, DouglasG. (1986). Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet, 327(8476), 307–310. https://doi.org/10.1016/S0140-6736(86)90837-8
  23. Nutt, K. R., Levy, J. K., & Tucker, S. J. (2016). Comparison of non-contact infrared thermometry and rectal thermometry in cats. Journal of Feline Medicine and Surgery, 18(10), 798–803. https://doi.org/10.1177/1098612X15596564
  24. Ozawa, S., Mans, C., & Beaufrère, H. (2017). Comparison of rectal and tympanic thermometry in chinchillas (Chinchilla lanigera). Journal of the American Veterinary Medical Association, 251(5), 552–558. https://doi.org/10.2460/javma.251.5.552
  25. Polat, D., & Yanmaz, L. E. (2024). Evaluating alternative temperature measurement sites in cats within a home environment: A comparison with rectal temperature. Veterinary Medicine and Science, 10(3). https://doi.org/10.1002/vms3.1423
  26. Rodrigues, T. T. F., & Cunha, G. N. (2019). Viabilidade das vias retal, axilar e oral para aferição da temperatura corporal de cães. Ars Veterinaria, 35(2), 43–49. https://doi.org/10.15361/2175-0106.2019v35n2p43-49
  27. Silva, M. A. J. G., Ferraz, P. F. P., Santos, L. M. D., Ferraz, G. A. E. S., Rossi, G., & Barbari, M. (2021). Effect of the spatial distribution of the temperature and humidity index in a New Zealand White rabbit house on respiratory frequency and ear surface temperature. Animals, 11(6), 1657. https://doi.org/10.3390/ani11061657
  28. Smith, V. A., Lamb, V., & McBrearty, A. R. (2015). Comparison of axillary, tympanic membrane and rectal temperature measurement in cats. Journal of Feline Medicine and Surgery, 17(12), 1028–1034. https://doi.org/10.1177/1098612X14567550
  29. Sousa, M. G., Carareto, R., Pereira-Junior, V. A., & Aquino, M. C. (2013). Agreement between auricular and rectal measurements of body temperature in healthy cats. Journal of Feline Medicine and Surgery, 15(4), 275–279. https://doi.org/10.1177/1098612X12464873
  30. Sousa, M. G., Carareto, R., Pereira-Junior, V. A., & Aquino, M. C. C. (2011). Comparison between auricular and standard rectal thermometers for the measurement of body temperature in dogs. The Canadian Veterinary Journal, 52(4), 403. https://pmc.ncbi.nlm.nih.gov/articles/PMC3058653/
  31. Southward, E. S., Mann, F. A., Dodam, J., & Wagner‐Mann, C. C. (2006). A comparison of auricular, rectal and pulmonary artery thermometry in dogs with anesthesia‐induced hypothermia. Journal of Veterinary Emergency and Critical Care, 16(3), 172–175. https://doi.org/10.1111/j.1476-4431.2005.00158.x
  32. Yanmaz, L. E., Doğan, E., Okumuş, Z., Şenocak, M. G., & Yildirim, F. (2015). Kangal Irkı Köpeklerde Kulak, Göz ve Rektal Isıların Karşılaştırılması. Kafkas Universitesi Veteriner Fakultesi Dergisi. https://doi.org/10.9775/kvfd.2015.13037
  33. Zakari, F. O., & Omontese, B. O. (2023). Comparison of axillary and inguinal temperature with rectal temperature in dogs at a veterinary teaching hospital. Journal of Small Animal Practice, 64(5), 330–336. https://doi.org/10.1111/jsap.13589

Make a Submission

Journal Metrics (2025) & Ranking

JOURNAL METRICS & RANKING (2025)

Impact Factor (2025) 0.5
5 years Impact Factor 1.0
JCR Quartile Q4
JIF Rank 146/170 (Veterinary Sciences)
SJR (2025) 0.208

Indexed in




Publisher

Keywords